Combining a powerful GSM module with an expandable alarm input module and AC/DC solid state relay output enables the NSGSM to be used as a simple SMS alarm upgrade module
as well as a flexible output controller. Using innovative caller ID technology allows the in-built relay to be controlled remotely by simply calling the GSM module using
a phone whose number has been validated in the module. Since the call is not answered, the relay is activated for free. Customizable SMS alarm messages allow meaningful
messages to be sent to selected recipients on activation and deactivation of the universal alarm input. All features including phone number restriction, SMS message
configuration etc can be remotely changed via password protected SMS from any mobile phone or by a PC using simple software combined with a GSM modem.
| Power | 7-16VDC @ 1A (peak) |
| Max. number of valid phone numbers | 340 |
| Alarm input | Opto-isolated 48 Volts AC/DC (Using appropriate current limiting resistor) |
| Control Relay output | Opto-Isolated 60 Volts AC/DC, 400mA Max |
| Telecommunications Frequency | Quad Band GSM |
| Dimensions | 80L 72W 30D (mm) |
For a brochure
For an instruction manual
For a PC based application program